Generator Failure
22.3.11
Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 7: Generator Failure Page 107
7. Generator Failure
7.1
Overloading the Generator
Please you make sure that the engine is not overloaded. An overloading in the long term can
harm the engine. In addition the exhaust gases are soot-blackened (environment).
The full rated output of the generator is primarily intended for brief use.
As fatigue strength should be calculated in the interest of a long life span of the engine
70% of the nominal load.
7.2
Starting Problems
7.2.1 VCS does not work
For start problems one chief cause is that the VCS doen not work. Check:
Is the voltage sense connection ok?
Check polatrity!
Terminal 7+8
Fig. 7.2.1-1: Terminal 7+8 on VCS
Is the shunt connection ok? Check pola-
trity!
Terminal 9+10
Fig. 7.2.1-2: Terminal 9+10 on VCS