![Fischer Panda Panda AGT-DC 5000 PMS Operation Manual Download Page 88](http://html1.mh-extra.com/html/fischer-panda/panda-agt-dc-5000-pms/panda-agt-dc-5000-pms_operation-manual_2294287088.webp)
Maintenance Instructions
Page 88 Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 6: Maintenance Instructions
22.3.11
Oil dipstick
With the help of the engine oil dipstick the
oil level is to examined. The prescribed fil-
ling level may not exceed the „Max“ mar-
king.
We recommend 2/3 oil level.
Fig. 6.2.1-7: Oil dipstick
6.3
Ventilating the fuel system
Normally, the fuel system is designed to bleed out air itself i.e. as soon as the electric starter
motor starts operation the fuel pump starts working and the fuel system will be ventilated after
some time automatically. It is nevertheless essential to bleed the system as follows prior to the
first operation (as all hoses are empty):
1. Switch the main power switch on control panel to „ON“. Functional components must illumi-
nate.
2. Push failure bypass switch and hold
tight. The electric fuel pump has to be
running audibly. By moving the failure
bypass switch you can hear the sole-
noid valve of the generator starting and
stopping (when the sound cover is
taken off).
Fig. 6.3-1: Failure bypass switch