Maintenance Instructions
22.3.11
Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 6: Maintenance Instructions Page 93
6.6
Replace of the v-belt
for the internal cooling water pump
The relative high ambient temperature in the closed sound insulated capsule (about 85°C) can be
a reason for a reduced lifespan of the v-belts. It is possible that the "softener" in the rubber com-
pound lose their effect after a short operating time because the air in the sound insulated capsule
can be relative warm and dry.
The v-belt must be controlled in a very short time interval. It can be happen to change the v-belt
after some weeks because of unfavorably conditions. Therefore the control is needed in an inter-
val of 100 operating hours. The v-belt ia a wearing part. It should be enough spare v-belts on
board. We suggest to stand by the according service-packet.
Loosen the fixing screw above the alter-
nator.
Fig. 6.6-1: Fixing screw - DC-alternator
Loosen the fixing screw below the alterna-
tor only a little bit.
Fig. 6.6-2: Fixing screw - DC-alternator
13
13