Installation Instructions
Page 66 Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 5: Installation Instructions
22.3.11
5.4.2 Ventilation at the first filling of the internal cooling water circuit
1. Fill up the external cooling water
expansion tank with coolant.
ATTENTION: „maximum fill level =
„max.“-mark.
The cover of the external expansion tank
temporary must be opened.
Fig. 5.4.2-1: Cooling water filler neck
2. Open vent screw on the pipe socket of
the internal cooling water pump. Close
the vent screw when air free water
comes out.
Check the water level in the expansion
tank during the vanting. Fill up if neces-
sary.
Never open the vent screw while the
generator is running.
Fig. 5.4.2-2: Ventilation screw -thermostat housing
3. Open vent screw on the thermostat
housing. Close the vent screw when
air free water comes out
Check the water level in the expansion
tank during the vanting. Fill up if neces-
sary.
Never open the vent screw while the
generator is running.
Fig. 5.4.2-3: Ventilation screw - water pump
10
10