Installation Instructions
Page 80 Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 5: Installation Instructions
22.3.11
Connector 2
T7
Terminal 7
+ UM
+ Battery sense voltage
+ 12V/24V/36V/48V
T8
Terminal 8
- UM
- Battery sense voltage
0V
Connector 3
T9
Terminal 9
+ U(Im)
Current sense
Max. + 48mV
T10
Terminal 10
- U(Im)
Current sense signal -
0V
5.8.1 Checking the VCS voltage control without requiring the generator to
run
Prerequisites :
1. Is VCS cable connected?
2. Is the cable for measurement voltage connected to VCS?
3. Is the cable for current measurement connected to VCS ?
4. Has graphite grease been smear on the spindle?
1. Remove connection 50 on starter motor
(white cable).
2. Switch “Power” on remote control
panel, Press “Start” button.
The VCS will keep the governor in the
maximum position whenever the starter
relay is activated. The actuator will return
to stationary (NULL) position when the
starter relay is deactivated.
Check that the actuator functions cor-
rectly.
Fig. 5.8.1-1: Connection 50