The Panda Generator
Page 52 Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 4: The Panda Generator
22.3.11
4.3.6 Sensors and switches for operating surveillance
Thermo-switch at cylinder head
The thermo-switch at the cylinder head
serves the monitoring of the generator
temperature. All thermo-switches for the
generators from Panda 6.000 upward are
two-pole and laidout as "openers".
110°C and 130°C
Fig. 4.3.6-1: Thermo-switch at cylinder head
Thermo-switch at watercooled exhaust
elbow
This thermo-swich is located at the water-
cooled exhaust elbow and monitors the
temperature of the fresh water circuit. The
switch measures at the hottest place,
because the flue gases lead from the
cylinder head into the exhaust elbow.
105/90°C
Fig. 4.3.6-2: Thermo-switch at exhaust elbow
Thermo-switch at exhaust connection
If the impeller pump drop out and delive-
res no more raw water, the exhaust con-
nection becomes extremely hot.
98/83°C
Fig. 4.3.6-3: Thermo-switch at exhaust connection