15 16-BIT PWM TIMER (T16A5)
S1C33L26 TECHNICAL MANUAL
Seiko Epson Corporation
15-17
D[15:6] Reserved
D5
CAPBOWIF: Capture B Overwrite Interrupt Flag Bit
Indicates whether the cause of capture B overwrite interrupt has occurred or not.
1 (R):
Cause of interrupt has occurred
0 (R):
No cause of interrupt has occurred (default)
1 (W):
Flag is reset
0 (W):
Ignored
CAPBOWIF is a T16A5 interrupt flag that is set to 1 when the capture B register is overwritten.
CAPBOWIF is reset by writing 1.
D4
CAPAOWIF: Capture A Overwrite Interrupt Flag Bit
Indicates whether the cause of capture A overwrite interrupt has occurred or not.
1 (R):
Cause of interrupt has occurred
0 (R):
No cause of interrupt has occurred (default)
1 (W):
Flag is reset
0 (W):
Ignored
CAPAOWIF is a T16A5 interrupt flag that is set to 1 when the capture A register is overwritten.
CAPAOWIF is reset by writing 1.
D3
CAPBIF: Capture B Interrupt Flag Bit
Indicates whether the cause of capture B interrupt has occurred or not.
1 (R):
Cause of interrupt has occurred
0 (R):
No cause of interrupt has occurred (default)
1 (W):
Flag is reset
0 (W):
Ignored
CAPBIF is a T16A5 interrupt flag that is set to 1 when the counter value is captured in the capture B
register.
CAPBIF is reset by writing 1.
D2
CAPAIF: Capture A Interrupt Flag Bit
Indicates whether the cause of capture A interrupt has occurred or not.
1 (R):
Cause of interrupt has occurred
0 (R):
No cause of interrupt has occurred (default)
1 (W):
Flag is reset
0 (W):
Ignored
CAPAIF is a T16A5 interrupt flag that is set to 1 when the counter value is captured in the capture A
register.
CAPAIF is reset by writing 1.
D1
CBIF: Compare B Interrupt Flag Bit
Indicates whether the cause of compare B interrupt has occurred or not.
1 (R):
Cause of interrupt has occurred
0 (R):
No cause of interrupt has occurred (default)
1 (W):
Flag is reset
0 (W):
Ignored
CBIF is a T16A5 interrupt flag that is set to 1 when the counter reaches the value set in the compare B
register.
CBIF is reset by writing 1.