
155
October 2017
Reference Manual
00809-0100-2240, Rev DA
Appendix C
F
OUNDATION
™
Fieldbus Block
Information
Resource block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 155
Analog input block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 161
Analog output block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 165
Register transducer block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 167
Measurement transducer block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 169
Average temperature transducer block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 174
Supported units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 176
C.1
Resource block
This section contains information on the Resource Block of the Rosemount
™
2240S Multi-Input
Temperature Transmitter.
The resource block defines the physical resources of the device. The resource block also handles
functionality that is common across multiple blocks. The block has no linkable inputs or outputs.
Table C-1. Resource Block Parameters
Index
Number
Parameter
Description
01
ST_REV
The revision level of the static data associated with the function
block.
02
TAG_DESC
The user description of the intended application of the block.
03
STRATEGY
The strategy field can be used to identify grouping of blocks.
04
ALERT_KEY
The identification number of the plant unit.
05
MODE_BLK
The actual, target, permitted, and normal modes of the block:
Target: The mode to “go to”
Actual: The mode the “block is currently in”
Permitted: Allowed modes that target may take on
Normal: Most common mode for actual
06
BLOCK_ERR
This parameter reflects the error status associated with the
hardware or software components associated with a block. It is a
bit string, so that multiple errors may be shown.
07
RS_STATE
State of the function block application state machine.
08
TEST_RW
Read/write test parameter - used only for conformance testing.
09
DD_RESOURCE
String identifying the tag of the resource which contains the Device
Description for
this resource.
10
MANUFAC_ID
Manufacturer identification number – used by an interface device
to locate the DD file for the resource.
Summary of Contents for Rosemount 2240S
Page 2: ......
Page 10: ...viii Reference Manual 00809 0100 2240 Rev DA Title Page October 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 2240 Rev DA Introduction October 2017 Introduction ...
Page 28: ...18 Reference Manual 00809 0100 2240 Rev DA Overview October 2017 Overview ...
Page 192: ...182 Reference Manual 00809 0100 2240 Rev DA Index October 2017 Index ...
Page 193: ......