STATUS_TANK_TEMP
Average Tank Temperature Status
22
EXCLUDE_SENSOR
Exclude Sensor. It is possible to exclude a temperature spot sensor
from the average calculation if the spot sensor is broken or delivers
erroneous measurement values.
23
INSERTION_ DISTANCE
Insertion Distance. This is the position offset for temperature
sensors. This offset is added to the configured position of each
sensor.
24
…
39
SENSOR_POSITION_1
…
SENSOR_ POSITION _16
Sensor Position for element no. 1 to 16.
Enter the position of each sensor element, measured as the
distance from the zero level (dipping datum plate) to the sensor
element. If average temperature sensor elements are used, enter
the position of the terminating level of each sensor element.
40
LEVEL
Level value used for average temperature calculation