C.6
Average temperature transducer block
The Average Temperature Transducer block contains temperature measurement data and configuration
parameters.
Table C-14. Average Temperature Transducer Block Parameters
Index
Number
Parameter
Description
1
ST_REV
The revision level of the static data associated with the function
block. The revision value increments each time a static parameter
value in the block is changed.
2
TAG_DESC
The user description of the intended application of the block.
3
STRATEGY
The strategy field can be used to identify grouping of blocks. This
data is not checked or processed by the block.
4
ALERT_KEY
The identification number of the plant unit. This information may
be used in the host for sorting alarms, etc.
5
MODE_BLK
The actual, target, permitted, and normal modes of the block.
Target: The mode to “go to”
Actual: The mode the “block is currently in”
Permitted: Allowed modes that target may take on
Normal: Most common mode for target
6
BLOCK_ERR
This parameter reflects the error status associated with the
hardware or software components associated with a block. It is a
bit string, so that multiple errors may be shown.
7
UPDATE_EVT
This alert is generated by any change to the static data.
8
BLOCK_ALM
The block alarm is used for all configuration, hardware, connection
failure or system problems in the block. The cause of the alert is
entered in the subcode field. The first alert to become active will
set the Active status in the Status parameter. As soon as the
Unreported status is cleared by the alert reporting task, another
block alert may be reported without clearing the Active status, if
the subcode has changed.
9
TRANSDUCER_DIRECTORY
Directory that specifies the number and starting indices of the
transducers in the transducer block.
10
TRANSDUCER_TYPE
Identifies the transducer.
11
TRANSDUCER_TYPE_VER
12
XD_ERROR
A transducer block alarm sub code. Provides additional error codes
related to transducer blocks.
13
COLLECTION_DIRECTORY
A directory that specifies the number, starting indices, and DD
Item ID’s of the data collections in each transducer within a
transducer block.
14
TEMPERATURE_UNIT
Measurement Unit for all temperature parameters
15
LENGTH_UNIT
Measurement Unit for all length parameters
16
TEMP_AVERAGE_LIQUID
Average Liquid Temperature
17
STATUS_AVG_LIQUID
Average Liquid Temperature Status
18
TEMP_AVERAGE_VAPOR
Average Vapor Temperature
19
STATUS_AVG_VAPOR
Average Vapor Temperature Status
20
TANK_TEMPERATURE
Average Tank Temperature
Summary of Contents for Rosemount 2240S
Page 2: ......
Page 10: ...viii Reference Manual 00809 0100 2240 Rev DA Title Page October 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 2240 Rev DA Introduction October 2017 Introduction ...
Page 28: ...18 Reference Manual 00809 0100 2240 Rev DA Overview October 2017 Overview ...
Page 192: ...182 Reference Manual 00809 0100 2240 Rev DA Index October 2017 Index ...
Page 193: ......