Chapter 27
| IP Interface Commands
IPv6 Interface
– 760 –
Example
This example assigns a link-local address of FE80::269:3EF9:FE19:6779 to VLAN 1.
Note that a prefix in the range of FE80~FEBF is required for link-local addresses, and
the first 16-bit group in the host address is padded with a zero in the form 0269.
Console(config)#interface vlan 1
Console(config-if)#ipv6 address FE80::269:3EF9:FE19:6779 link-local
Console(config-if)#end
Console#show ipv6 interface
VLAN 1 is up
IPv6 is enabled.
Link-local address:
fe80::269:3ef9:fe19:6779%1/64
Global unicast address(es):
2001:db8:0:1:2e0:cff:fe02:fd/64, subnet is 2001:db8:0:1::/64[EUI]
2001:db8:2222:7272::72/96, subnet is 2001:db8:2222:7272::/96
Joined group address(es):
ff02::2
ff02::1:ff19:6779
ff02::1:ff00:0
ff02::1:ff00:72
ff02::1:ff02:fd
ff02::1:2
ff02::1
IPv6 link MTU is 1500 bytes
ND DAD is enabled, number of DAD attempts: 1.
ND retransmit interval is 1000 milliseconds
ND advertised retransmit interval is 0 milliseconds
ND reachable time is 30000 milliseconds
ND advertised reachable time is 0 milliseconds
ND advertised router lifetime is 1800 seconds
Console#
Related Commands
ipv6 enable (760)
show ipv6 interface (763)
ipv6 enable
This command enables IPv6 on an interface that has not been configured with an
explicit IPv6 address. Use the
no
form to disable IPv6 on an interface that has not
been configured with an explicit IPv6 address.
Syntax
[
no
]
ipv6 enable
Default Setting
IPv6 is disabled
Command Mode
Interface Configuration (VLAN)
Command Usage
◆
This command enables IPv6 on the current VLAN interface and automatically
generates a link-local unicast address. The address prefix uses FE80, and the
Summary of Contents for AS5700-54X
Page 42: ...Contents 42...
Page 44: ...Figures 44...
Page 52: ...Tables 52...
Page 54: ...Section I Getting Started 54...
Page 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Page 210: ...Chapter 6 Remote Monitoring Commands 210...
Page 358: ...Chapter 9 Access Control Lists ACL Information 358...
Page 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Page 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Page 442: ...Chapter 16 Address Table Commands 442...
Page 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Page 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Page 544: ...Chapter 20 Quality of Service Commands 544...
Page 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Page 680: ...Chapter 23 LLDP Commands 680...
Page 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Page 732: ...Chapter 25 Domain Name Service Commands 732...
Page 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Page 1072: ...Section III Appendices 1072...
Page 1102: ...List of CLI Commands 1102...
Page 1115: ......
Page 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...