Chapter 4
| System Management Commands
System Status
– 121 –
◆
There are two thermal detectors in the switch The first detector is near the air
flow intake vents. The second detector is near the switch ASIC and CPU.
Example
Console#show system
System Description : AOS5700-54X
System OID String : 1.3.6.1.4.1.259.12.1.2
System Information
System Up Time : 0 days, 5 hours, 44 minutes, and 42.28 seconds
System Name :
System Location :
System Contact :
MAC Address (Unit 1) : 00-00-0C-00-00-FD
Web Server : Enabled
Web Server Port : 80
Web Secure Server : Enabled
Web Secure Server Port : 443
Telnet Server : Enabled
Telnet Server Port : 23
Jumbo Frame : Disabled
System Fan:
Force Fan Speed Full : Disabled
Unit 1
Fan 1: Ok
System Temperature:
Unit 1
Temperature 1: 39 degrees Temperature 2: 37 degrees
Temperature 3: 38 degrees Temperature 4: 31 degrees
Temperature 5: 31 degrees Temperature 6: 29 degrees
Temperature 7: 29 degrees Temperature 8: 36 degrees
Temperature 9: 36 degrees
Main Power Status : Up
Redundant Power Status : Not present
Console#
Table 14: show system – display description
Parameter
Description
System Description
Brief description of device type.
System Object ID
MIB II object ID for switch’s network management subsystem.
System Up Time
Length of time the management agent has been up.
System Name
Name assigned to the switch system.
System Location
Specifies the system location.
System Contact
Administrator responsible for the system.
MAC Address
MAC address assigned to this switch.
Web Server/Port
Shows administrative status of web server and UDP port number.
Web Secure Server/Port
Shows administrative status of secure web server and UDP port
number.
Telnet Server/Port
Shows administrative status of Telnet server and TCP port number.
Summary of Contents for AS5700-54X
Page 42: ...Contents 42...
Page 44: ...Figures 44...
Page 52: ...Tables 52...
Page 54: ...Section I Getting Started 54...
Page 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Page 210: ...Chapter 6 Remote Monitoring Commands 210...
Page 358: ...Chapter 9 Access Control Lists ACL Information 358...
Page 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Page 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Page 442: ...Chapter 16 Address Table Commands 442...
Page 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Page 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Page 544: ...Chapter 20 Quality of Service Commands 544...
Page 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Page 680: ...Chapter 23 LLDP Commands 680...
Page 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Page 732: ...Chapter 25 Domain Name Service Commands 732...
Page 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Page 1072: ...Section III Appendices 1072...
Page 1102: ...List of CLI Commands 1102...
Page 1115: ......
Page 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...