Chapter 24
| CFM Commands
Continuity Check Operations
– 706 –
show ethernet cfm
errors
This command displays the CFM continuity check errors logged on this device.
Syntax
show ethernet cfm errors
[
domain
domain-name
|
level
level-id
]
domain-name –
Domain name. (Range: 1-43 alphanumeric characters)
level-id
– Authorized maintenance level for this domain. (Range: 0-7)
Default Setting
None
Command Mode
Privileged Exec
Example
Console#show ethernet cfm errors
Level VLAN MPID Interface Remote MAC Reason MA Name
----- ---- ---- --------- ----------------- ---------------- ----------------
5 2 40 Eth 1/1 ab.2f.9c.00.05.01 LEAK provider_1_2
Console#
Table 137: show ethernet cfm errors - display description
Field
Description
Level
Maintenance level associated with this entry.
VLAN
VLAN in which this error occurred.
MPID
Identifier of remote MEP.
Interface
Port at which the error was recorded
Remote MAC
MAC address of remote MEP.
Reason
Error types include:
LEAK – MA
x
is associated with a specific VID list
*
, one or more of the VIDs
in this MA can pass through the bridge port, no MEP is configured facing
outward (down) on any bridge port for this MA, and some other MA
y
, at a
higher maintenance level, and associated with at least one of the VID(s)
also in MA
x
, does have a MEP configured on the bridge port.
VIDS – MA
x
is associated with a specific VID list
on this MA on the bridge
port, and some other MA
y
, associated with at least one of the VID(s) also
in MA
x
, also has an Up MEP configured facing inward (up) on some bridge
port.
EXCESS_LEV – The number of different MD levels at which MIPs are to be
created on this port exceeds the bridge's capabilities.
OVERLAP_LEV – A MEP is created for one VID at one maintenance level,
but a MEP is configured on another VID at an equivalent or higher level,
exceeding the bridge's capabilities.
* This definition is based on the IEEE 802.1ag standard. Current software for this switch only supports a single
VLAN per MA. However, since it may interact with other devices which support multiple VLAN assignments per
MA, this error message may be reported.
MA
The maintenance association for this entry.
Summary of Contents for AS5700-54X
Page 42: ...Contents 42...
Page 44: ...Figures 44...
Page 52: ...Tables 52...
Page 54: ...Section I Getting Started 54...
Page 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Page 210: ...Chapter 6 Remote Monitoring Commands 210...
Page 358: ...Chapter 9 Access Control Lists ACL Information 358...
Page 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Page 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Page 442: ...Chapter 16 Address Table Commands 442...
Page 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Page 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Page 544: ...Chapter 20 Quality of Service Commands 544...
Page 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Page 680: ...Chapter 23 LLDP Commands 680...
Page 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...