Chapter 24
| CFM Commands
Defining CFM Structures
– 690 –
ma index name
This command creates a maintenance association (MA) within the current
maintenance domain, maps it to a customer service instance (S-VLAN), and sets the
manner in which MIPs are created for this service instance. Use the
no
form with
the
vlan
keyword to remove the S-VLAN from the specified MA. Or use the
no
form
with only the
index
keyword to remove the MA from the current domain.
Syntax
ma index
index
name
ma-name
[
vlan
vlan-list
[
mip-creation
type
]]
no ma index
index
[
vlan
vlan-list
]
index –
MA identifier. (Range: 1-2147483647)
ma-name –
MA name. (Range: 1-43 alphanumeric characters)
vlan-list
- Separate nonconsecutive VLAN identifiers with a comma and no
spaces; use a hyphen to designate a range of IDs. (Range: 1-4094).
type
– Specifies the CFM protocol’s creation method for maintenance
intermediate points (MIPs) in this MA:
default
– MIPs can be created for this MA on any bridge port through
which the MA’s VID can pass.
explicit
– MIPs can be created this MA only on bridge ports through
which the MA’s VID can pass, and only if a maintenance end point (MEP)
is created at some lower MA Level.
none
– No MIP can be created for this MA.
Default Setting
10 seconds
Command Mode
CFM Domain Configuration
Command Usage
◆
The maintenance domain used to enter CFM domain configuration mode, the
MA name and VLAN identifier specified by this command, and the DSAPs
configured with the
command create a unique service
instance for each customer.
◆
If only the MA index and name are entered for this command, the MA will be
recorded in the domain database, but will not function. No MEPs can be
created until the MA is associated with a service VLAN.
◆
Note that multiple domains at the same maintenance level (see the
command) cannot have an MA on the same VLAN. Also, each MA
name must be unique within the CFM-managed network.
◆
The first VLAN entered in the list by this command is the primary VLAN, and is
the VLAN on which all CFM functions are executed.
Summary of Contents for AS5700-54X
Page 42: ...Contents 42...
Page 44: ...Figures 44...
Page 52: ...Tables 52...
Page 54: ...Section I Getting Started 54...
Page 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Page 210: ...Chapter 6 Remote Monitoring Commands 210...
Page 358: ...Chapter 9 Access Control Lists ACL Information 358...
Page 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Page 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Page 442: ...Chapter 16 Address Table Commands 442...
Page 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Page 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Page 544: ...Chapter 20 Quality of Service Commands 544...
Page 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Page 680: ...Chapter 23 LLDP Commands 680...
Page 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Page 732: ...Chapter 25 Domain Name Service Commands 732...
Page 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Page 1072: ...Section III Appendices 1072...
Page 1102: ...List of CLI Commands 1102...
Page 1115: ......
Page 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...