Chapter 24
| CFM Commands
Continuity Check Operations
– 701 –
Continuity Check Operations
ethernet cfm cc ma
interval
This command sets the transmission delay between continuity check messages
(CCMs). Use the
no
form to restore the default settings.
Syntax
ethernet cfm cc md
domain-name
ma
ma-name
interval
interval-level
no ethernet cfm cc ma
ma-name
interval
domain-name –
Domain name. (Range: 1-43 alphanumeric characters)
ma-name –
Maintenance association name. (Range: 1-43 alphanumeric
characters)
interval-level –
The transmission delay between connectivity check
messages. The setting for this parameter is expressed as levels 4 through 7,
which in turn map to specific intervals of time. (CCM interval field options:
4 - 1 second, 5 - 10 seconds, 6 - 1 minute, 7 - 10 minutes)
Default Setting
4 (1 second)
Command Mode
Global Configuration
Command Usage
◆
CCMs provide a means to discover other MEPs and to detect connectivity
failures in an MA. If any MEP fails to receive three consecutive CCMs from any
other MEPs in its MA, a connectivity failure is registered. The interval at which
Port State
Port states include:
Up – The port is functioning normally.
Blocked – The port has been blocked by the Spanning Tree Protocol.
No port state – Either no CCM has been received, or nor port status TLV
was received in the last CCM.
Interface State
Interface states include:
No Status – Either no CCM has been received, or no interface status TLV
was received in the last CCM.
Up – The interface is ready to pass packets.
Down – The interface cannot pass packets.
Testing – The interface is in some test mode.
Unknown – The interface status cannot be determined for some reason.
Dormant – The interface is not in a state to pass packets but is in a pending
state, waiting for some external event.
Not Present – Some component of the interface is missing.
isLowerLayerDown – The interface is down due to state of the lower layer
interfaces.
Crosscheck Status
Shows if crosscheck function has been enabled.
Table 136: show ethernet cfm maintenance-points remote detail - display
Field
Description
Summary of Contents for AS5700-54X
Page 42: ...Contents 42...
Page 44: ...Figures 44...
Page 52: ...Tables 52...
Page 54: ...Section I Getting Started 54...
Page 80: ...Chapter 1 Initial Switch Configuration Setting the System Clock 80...
Page 210: ...Chapter 6 Remote Monitoring Commands 210...
Page 358: ...Chapter 9 Access Control Lists ACL Information 358...
Page 418: ...Chapter 12 Port Mirroring Commands RSPAN Mirroring Commands 418...
Page 436: ...Chapter 15 UniDirectional Link Detection Commands 436...
Page 442: ...Chapter 16 Address Table Commands 442...
Page 506: ...Chapter 18 VLAN Commands Configuring VXLAN Tunneling 506...
Page 526: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 526...
Page 544: ...Chapter 20 Quality of Service Commands 544...
Page 652: ...Chapter 22 Multicast Filtering Commands MLD Proxy Routing 652...
Page 680: ...Chapter 23 LLDP Commands 680...
Page 722: ...Chapter 24 CFM Commands Delay Measure Operations 722...
Page 732: ...Chapter 25 Domain Name Service Commands 732...
Page 790: ...Chapter 27 IP Interface Commands ND Snooping 790...
Page 1072: ...Section III Appendices 1072...
Page 1102: ...List of CLI Commands 1102...
Page 1115: ......
Page 1116: ...AS5700 54X AS6700 32X E032016 ST R02 149100000198A...