Chapter 4 Parameter Functions
|
HES Series
4-4
Pr.
Explanation
Settings
Factory
Setting
VF
FO
C
P
G
FO
C
P
M
00-12 Pressure Command Filter Time
PI
0.000~1.000 sec
0.000
○
○
○
00-13 Flow Command Filter Time QI 0.000~1.000 sec
0.000
○
○
○
00-14 Pressure Command Percentage
(Max)
0.0~100.0% 100.0
○
○
○
00-15 Pressure Command Percentage
(Mid)
0.0~100.0% 50.0
○
○
○
00-16 Pressure
Command
Percentage(Min)
0.0~100.0% 0.0
○
○
○
00-17 Flow Command Percentage
(Max)
0.0~100.0% 100.0
○
○
○
00-18 Flow Command Percentage
(Mid)
0.0~100.0% 50.0
○
○
○
00-19 Flow Command Percentage
(Min)
0.0~100.0% 0.0
○
○
○
00-20 Proportional Gain 1 (P)
0.0~1000.0
50.0
○
○
○
00-21 Integral Time 1 (I)
0.00~500.00 sec
2.00
○
○
○
00-22 Proportional Gain 2 (P)
0.0~1000.0
50.0
○
○
○
00-23 Integral Time 2 (I)
0.00~500.00 sec
2.00
○
○
○
00-24 Proportional Gain 3 (P)
0.0~1000.0
50.0
○
○
○
00-25 Integral Time 3 (I)
0.00~500.00 sec
2.00
○
○
○
00-26 Pressure Stabilization Zone
0~100%
25
○
○
○
00-27 Bottom
Pressure
0.0~100.0%
1.0
○
○
○
00-28 Pressure Relief Speed
0~100%
25
○
○
○
00-29 Pressure Command Rising
Slope
0~1000ms 0
○
○
○
00-30 Pressure Command Descending
Slope
0~1000ms 100
○
○
○
00-31 Flow Command Rising Slope
0~1000 ms
80
○
○
○
00-32 Flow Command Descending
Slope
0~1000 ms
80
○
○
○
00-33 Value Open Delay Time
0~200 ms
0
○
○
○
00-34 High/Low Flow Reference Point
Switch
0.00~100.00 %
50.00
○
○
○
00-35 Over Pressure Detection Level 0~250 Bar
230
○
○
○
00-36 Pressure Feedback Fault
Detection
0: No function
1: Enable (for pressure feedback output signal at 1-5V
only)
0
○
○
○
00-37 Derivative
Gain
0.0~100.0
%
0.0
○
○
○
Call 1(800)985-6929 for Sales