Appendix B Optional Accessories
|
HES Series
B-15
B-6 Brake Unit
Individual Parts and Function Explanation
Input Voltage Setup
Pin
Activated Loop
Terminal
Fault Loop Terminal
Power Input Terminal
+(P) -(N)
,
Brake Resistance
Terminal
B1, B2
CHARGE ACT
ERR
480V
460V
440V
415V
400V
380V
240V
230V
220V
210V
200V
190V
Input Voltage Setup
VFDB-4030/4050 Series
Set voltage as indicated on
the left.
Default is 460V.
VFDB-2015/2022 Series
Set voltage as indicated
on the right
Default is 230V.
Power
Indicator
Brake Action
Indicator
Fault
Indicator
Input voltage setting for VFDB-2015/2022/4030/4045
The Voltage Settings
1. Adjust Voltage: The + (P) and
–
(N) sides of the hydraulic servo motor controller are the DC power
source of the control unit. Therefore, after wiring and before operation, it is very important to set the
voltage of the control unit according to the input voltage of the hydraulic servo motor controller.
This setting will affect the state of activation voltage of the control unit. The following table shows
the state address of individual voltage actions.
Voltage: 230 VAC
Braking Start-up voltage
DC Bus (+(P), -(N)) Voltage
Voltage: 230 VAC
Braking Start-up voltage
DC Bus (+(P), -(N)) Voltage
190Vac 330Vdc 380Vac 660Vdc
200Vac 345Vdc 400Vac 690Vdc
210Vac 360Vdc 415Vac 720Vdc
220Vac 380Vdc 440Vac 760Vdc
230Vac 400Vdc 460Vac 800Vdc
240Vac 415Vdc 480Vac 830Vdc
Table 1: The Selection of Power Voltage and Operation Potential of PN DC Voltage