Chapter 4 Parameter Functions
|
HES Series
4-9
03 Digital/Analog I/O Parameters
: The parameter can be set during operation.
Pr.
Explanation
Settings
Factory
Setting
VF
FO
C
P
G
FO
C
P
M
03-00 Multi-functional Input Command
3 (MI3)
0
○
○
○
03-01 Multi-functional Input Command
4 (MI4)
0
○
○
○
03-02 Multi-functional Input Command
5 (MI5)
0: No function
44: Injection signal input
45: Combination/Diversion signal input
0
○
○
○
03-03 Digital Input Response Time
0.001~ 30.000 sec
0.005
○
○
○
03-04 Digital Input Operation Direction 0~65535
0
○
○
03-05 Multi-functional Output 1 (Relay
1)
11
○
○
○
03-06 Multi-functional Output 2 (MO1)
0
○
○
○
03-07 Multi-functional Output 3 (MO2)
0: No function
1: Operation Indication
9: Hybrid Servo Controller is ready
11: Malfunction indication
44: Ram pump flow switch signal
45: Motor fan control signal
0
○
○
○
03-08 Multi-functional
Output
Direction 0~65535
0
○
03-09 Low-pass Filter Time of Keypad
Display
0.001~65.535 sec
0.010
○
○
○
03-10 Pressure Feedback Maximum
Output Voltage
5~10 V
10
○
○
○
03-11 Pressure Feedback Minimum
Output Voltage
0~1 V
0
○
○
○
03-12 Reserved
03-13
Combination Sever/Slave
Selection
0: No function
1: Server
2: Slave
0
○
○
○
03-14 Slave to Server Flow Rate
0.0~65535.5 %
100.0
○
○
○
03-15
Source of the Master Frequency
Command
0: Digital keypad
1: RS-485 serial communication
2~5: Reserved
0
○
○
○
03-16 Slave Motor Reverse Rotation
Pressure Relief Torque Limit
0~500% 20
○
○
○
03-17 Reserved
03-18 Transmission
Fault
Treatment
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
3: No action and no display
3
○
○
○
03-19 Time Out Detection
0.0~100.0 sec
0.0
○
○
○
03-20 Start-up Display Selection
0: Display the frequency command value (LED F)
1: Display the actual output frequency (LED H)
2: Multi-function display, see Pr.00-04
3: Display the output current (A)
0
○
○
○