Chapter 4 Parameter Functions
|
HES Series
4-3
Pr.
Explanation
Settings
Factory
Setting
VF
FO
C
P
G
FO
C
P
M
00-04 Content of Multi-function Display 0: Displays the output current (A) from Hybrid Servo
Controller to motor.
1: Reserved
2: Displays the actual output frequency (H) of the
Hybrid Servo Controller.
3: Display the DC bus voltage (U) of the Hybrid Servo
Controller.
4: Displays the U, V and W output voltage (E) of the
Hybrid Servo Controller.
5: Displays the output power factor and angle (n) of the
Hybrid Servo Controller.
6: Displays the output power kW (P) of the Hybrid
Servo Controller.
7: Displays the actual speed (rpm, r) of the Hybrid
Servo Controller.
8: Displays the estimated output torque N-m (%) of the
Hybrid Servo Controller.
9: Displays the PG feedback (G).
10: Reserved
11: Displays the signal value % of the PO analog input
terminal.
12: Displays the signal value % of the PI analog input
terminal.
13: Displays the signal value % of the AUI analog input
terminal.
14: Displays the heat-sink temperature
°
C (t.) of the
Hybrid Servo Controller.
15: The temperature
°
C of the power module IGBT.
16: The ON/OFF status of the digital input.
17: The ON/OFF status of the digital output.
18: Reserved
19: The status of the corresponding CPU pins of digital
input.
20: The status of the corresponding CPU pins of digital
output.
21~24: Reserved.
25: Displays the signal value % of the QI analog input
terminal.
26: Displays the actual pressure value (Bar).
27: Displays Wh.
28: Displays motor temperature (currently supports
KTY84 only)
0
○
○
○
00-05
0: Output frequency (Hz)
0
○
○
○
Analog Output Selection
1: Frequency command (Hz)
○
○
○
2: Motor speed (Hz)
○
○
○
3: Output current (A)
○
○
4: Output voltage
○
○
○
5: DC Bus voltage
○
○
○
6: Power factor
○
○
○
7:
Power
8: Output torque
9:
PO
10:
PI
11:
AUI
○
○
○
12~20:
Reserved
○
○
○
00-06 User-defined: Display actual
motor speed in rpm
0~39999 rpm
0
○
○
○
00-07 Maximum Value of Pressure
Command
0~250 Bar
250
○
○
○
00-08 Maximum Value of Pressure
Feedback
0~400 Bar
250
○
○
○
00-09 Pressure Control Mode
0: Speed Control
1: Pressure Control
0
○
○
○
00-10
Speed
Bandwidth
0~40Hz
20
○
○
00-11 Pressure Feedback Filter Time
PO
0.000~1.000 sec
0.000
○
○
○
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales