Chapter 4 Parameter Functions
|
HES Series
4-10
4-2 Description of Parameter Settings
00 System Parameters
: The parameter can be set during operation.
Identity Code of the Hybrid Servo Controller
Control Mode
VF FOCPG
FOCPM
Factory setting: ##
Settings Read Only
Hybrid Servo Controller
Control Mode
VF FOCPG
FOCPM
Factory setting: ##
Settings Read Only
Pr.00-00 System parameters determine the Hybrid Servo Controller capacity. They are set in the
system before shipping. Also, the current of Pr. 00-01 can be retrieved to check the nominal current of
respective models. Pr. 00-00 corresponds to the current display in Pr. 00-01.
230V Series
kW
5.5 7.5 11 15 18.5 22 30 37
HP
7.5 10 15 20 25 30 40 50
Pr.00-00
12 14 16 18 20 22 24 26
460V Series
kW
5.5 7.5 11 15 18.5
22 30 37 45 55 75
HP
7.5 10 15 20 25 30 40 50 60 75 100
Pr.00-00
13 15 17 19 21 23 25 27 29 31 33
Parameter Reset
Control Mode
VF FOCPG
FOCPM
Factory setting: 0
Settings 0: No function
5: Resets to Wh display value in stop status.
10: All parameters are reset to factory settings (60Hz).
Set the parameter to “10” to reset the parameter to the Factory setting.
Software Version
Control Mode
VF FOCPG
FOCPM
Factory setting: #.##
Settings Read Only
Content Multi-function Display
Control Mode
VF FOCPG
FOCPM
Factory setting: 0
Settings 0: Displays the output current (A) from Hybrid Servo
Controller to motor.
U
1: Reserved
2: Displays the actual output frequency (H) of the Hybrid
Servo Controller.
U
3: Display the DC bus voltage (U) of the Hybrid Servo
Controller.
U
4: Displays the U, V and W output voltage (E) of the Hybrid
Servo Controller.
U
5: Displays the output power factor and angle (n) of the
Hybrid Servo Controller.
U