Chapter 3 Flow of machine Adjustment
|
HES Series
3-12
Pr. 03-13
0: No function
1: Master station
2: Slave station
Resume power supply to slave machine after power outage
Set slave machine to speed control mode
Pr. 00-09 = 0 Speed control mode
Speed Control Mode
Pr. 00-09
0: Speed control
1: Pressure control
At this point, the Master machine can be adjusted by the following steps 3-8 described above.
Steps of Configuration Flow for System
Combining/Diversion
Follow the associated descriptions in Chapter 2 to lay out the wiring.
In the diversion state, follow steps 1-8 described above to individually adjust the parameters of
each driver.
In the combined state, refer to the configuration flow for combined system.
Complete the above steps.
Set the Master machine to run in pressure control mode.
Pr. 00-09 = 1 Pressure control mode
Pressure control mode
Pr. 00-09
0: Speed control
1: Pressure control
Set the Slave machine to run in speed control mode
Pr. 00-09 = 0 Speed control mode
Speed control mode
Pr. 00-09
0: Speed control
1: Pressure control
Set the multi-functional input states of Master/Slave separately
Pr. 03-00~03-02 = 45 Combined/Diversion signal input
Multi-functional input
Pr. 03-00~
03-02
0: No function
45: Input of Combined/Diversion signal
Execute the entire combined/diversion action through the position machine.