Chapter 4 Parameter Functions
|
HES Series
4-17
01 Motor Parameters
: The parameter can be set during operation.
Control Mode
Control Mode
VF FOCPG
FOCPM
Factory setting: 5
Settings 0: V/F Control
1: Reserved
2: Reserved
3: FOC Vector C Encoder (FOCPG)
4: Reserved
5: FOC PM control (FOCPM)
6: Reserved
This parameter determines the control mode of the Hybrid Servo Controller.
0: V/F-Users can design the V/F ratio according to their needs with an induction motor.
3: FOC Vector C Encoder (FOCPG) with an induction motor.
5: FOCPM Vector C Encoder (FOCPG) with a permanent motor.
Source of the Operation Command
Control Mode
VF FOCPG
FOCPM
Factory setting: 1
0: Digital keypad
1: External terminals. Keypad STOP disabled.
Settings
2: RS-485 serial communication. Keypad STOP disabled.
Press the PU key on the panel until the “PU” indicator illuminates to activate the RUN, JOG and STOP
keys.
Maximum Motor Operation Frequency
Control Mode
VF FOCPG
FOCPM
Factory setting: 60.00/50.00
Settings 50.00~600.00Hz
Sets the maximum operation frequency range of the motor. This setting should correspond to the system
maximum flow.
Nominal Motor Frequency
Control Mode
VF FOCPG
FOCPM
Factory setting: 60.00/50.00
Settings 0.00~600.00Hz
In general, this value is set according to the specifications on the motor nameplate; i.e. the nominal
voltage frequency for motor operation. If the motor voltage frequency is 60Hz, set the value to 60Hz. If
the motor voltage frequency is 50Hz, set the value to 50Hz.
Nominal Motor Voltage
Control Mode
VF FOCPG
Factory setting: 220.0/440.0
230V Series: 0.1~255.0V
Settings
460V Series: 0.1~510.0V
In general, this value is set according to the specifications on the motor nameplate; i.e. the