Chapter 1 Use and Installation
|
HES Series
1-7
Pipelines & Connections
Remove all protection caps on the pump
Choose suitable oil tube and connectors (Maximum intake flow rate 1m/s)
Recommended Specifications of intake oil tube
Flow Rate(L/min)
Tube Diameter (inch)
Length (m)
63
Above 1.25
Within 1.5
80
Above 1.5
Within 1.5
100
Above 1.75
Within 1.5
125
Above 2
Within 1.5
160
Above 2.25
Within 1.5
200
Above 2.5
Within 1.5
Absolute intake oil pressure: Maximum 2 bar
Prior to assembly, the iron dusts in the connectors and oil tubes must be removed.
The filter for the oil inlet must be above 150mesh.
NOTE
For safety, please install safety valve in the oil line loop.
Do not add check valve to the oil outlet of the oil pump to avoid poor response of Hybrid Energy System.
Hybrid Servo Controller
Please install the Hybrid Servo Controller in an environment with the following conditions to ensure
safe product operation:
Conditions of
Operation
Environment
Environment Temperature
Relative Humidity
Pressure
Installation heights
Vibration
-10°C~ +45°C
<90%
,
No condensation
86 ~ 106 kPa
<1000m
<20Hz: 9.80 m/s
2
(1G) max; 20~50H:5.88 m/s
2
(0.6G) max
Conditions of
Storage and
Shipping
Environment
Environment Temperature
Relative Humidity
Pressure
Vibration
-20°C~ +60°C (-4°F ~ 140°F)
<90%
,
No condensation
86 ~ 106 kPa
<20Hz: 9.80 m/s
2
(1G) max; 20 ~ 50Hz: 5.88 m/s
2
(0.6G) max
Contamination
Protection Grade
2nd Grade: suitable for factory environments with medium to low contamination
Installation Space
H
Air Flow
H
W
W
Call 1(800)985-6929 for Sales
deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com