#975 ZERO CLEARANCE KIT

Sept 2003 

INSTALLATION INSTRUCTIONS

 

approved for use only with 

VALOR MODEL 922 Adorn Fireplace 

1.  GENERAL

Model 975ZCK zero clearance kit must be used when installing Fireplace Model 922 into 
an enclosure constructed of combustible material and connected to an approved venting 
system. Either the 923 Adorn or the 539/549 Windsor Arch cast fronts may be used with 
the 922 fireplace installed in the 975 Zero Clearance Kit. 

 

2.  FRAMING.

 

Minimum clearances to combustible materials and framing details are shown in fig.1. 
Though not mandatory, we recommend that a hard surfaced hearth area be maintained in 
front of the fireplace for both aesthetic and maintenance purposes. This may be finished 
in brick, ceramic tile, marble, etc. Raising the hearth slightly will help to minimize dust 
and lint accumulation under the unit. Refer to the 922 installation manual for mantle 
clearances as they vary with the different from trims. 

 

To enable the heater to be installed correctly the height of the finished hearth must 
be known before installing this kit, please note the bottom of the kit must be 
installed at the planned finished hearth height (including tile etc.). 

 
 

 

 

 

Fig. 1 framing dimensions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

4000 483 