Chapter 11 Summary of Parameter Settings
CT2000 Series
11-25
Pr.
Explanation
Settings
Factory
Setting
06-32 Output Frequency at Malfunction
0.00~599.00Hz
Read
only
06-33 Output Voltage at Malfunction
0.0~6553.5 V
Read
only
06-34 DC Voltage at Malfunction
0.0~6553.5 V
Read
only
06-35 Output Current at Malfunction
0.00~6553.5 Amp
Read
only
06-36 IGBT Temperature at Malfunction -3276.7~3276.7
℃
Read
only
06-37
Capacitance Temperature at
Malfunction
-3276.7~3276.7
℃
Read
only
06-38
Motor Speed in rpm at
Malfunction
-32767~32767 rpm
Read
only
06-39 Torque Command at Malfunction
-3276.7~3276.7 %
Read
only
06-40
Status of Multi-function Input
Terminal at Malfunction
0000h~FFFFh
Read
only
06-41
Status of Multi-function Output
Terminal at Malfunction
0000h~FFFFh
Read
only
06-42 Drive Status at Malfunction
0000h~FFFFh
Read
only
06-43 Reserved
06-44 Reserved
06-45 Treatment to Output Phase Loss
Detection (OPHL)
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning
3
06-46 Deceleration Time of Output
Phase Loss
0.000~65.535 sec
0.500
06-47 Current
Bandwidth
0.00~100.00%
1.00
06-48 DC Brake Time of Output Phase
Loss
0.000~65.535sec
0.100
06-49 LvX
Auto
Reset
0: Disable
1: Enable
0
06-50 Time for Input Phase Loss
Detection
0.00~600.00 sec.
0.20
06-51 Reserved
06-52 Ripple of Input Phase Loss
460V model: 0.0~320.0 Vdc
60.0
06-53 Treatment for the detected Input
Phase Loss (OrP)
0: warn and ramp to stop
1: warn and coast to stop
0
06-54 Reserved
06-55 Derating
Protection
0: constant rated current and limit carrier wave by
load current and temperature
1: constant carrier frequency and limit load current
by setting carrier wave
2: constant rated current(same as setting 0), but
close current limit
0
06-56 PT100 Detected Level 1
0.000~10.000V
5.000
06-57 PT100 Detected Level 2
0.000~10.000V
7.000
06-58 PT100 Level 1 Frequency
Protect
0.00~599.00Hz
0.00
06-59 PT100 Activation Level Delay
Time
0~6000 sec.
60
Summary of Contents for CT2000 Series
Page 5: ...Chapter 1 Introduction CT2000 Series 1 2 Model Name VFD 750 CT 43 F 00 A6 Serial Number...
Page 22: ...Chapter 1 Introduction CT2000 Series 1 19 Digital Keypad KPC CC01 KPC CE01 Unit mm inch...
Page 23: ...Chapter 1 Introduction CT2000 Series 1 20 This page intentionally left blank...
Page 41: ...Chapter 4 Wiring CT2000 Series 4 6 This page intentionally left blank...
Page 71: ...Chapter 7 Optional Accessories CT2000 Series 7 18 Wall Mounting Embedded Mounting...
Page 87: ...Chapter 8 Optional Cards CT2000 Series 8 8 PG Card intallation...
Page 88: ...Chapter 8 Optional Cards CT2000 Series 8 9 Disconneting the extension card...
Page 92: ...Chapter 8 Optional Cards CT2000 Series 8 13 PG2 Wiring Diagram...
Page 95: ...Chapter 8 Optional Cards CT2000 Series 8 16 PG2 Wiring Diagram...
Page 117: ...Chapter 8 Optional Cards CT2000 Series 8 38 This page intentionally left blank...
Page 259: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 11...
Page 260: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 12...
Page 263: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 15...
Page 266: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 18...
Page 397: ...Chapter 13 Warning Codes CT2000 Series 13 8 This page intentionally left blank...
Page 407: ...Chapter 14 Fault Codes and Descriptions CT2000 Series 14 10 This page intentionally left blank...
Page 489: ...Chapter 16 PLC Function CT2000 Series 16 48 LD X1 Load Contact a of X1 OUT Y1 Drive Y1 coil...
Page 592: ...Chapter 16 PLC Function CT2000 Series 16 151...
Page 594: ...Chapter 16 PLC Function CT2000 Series 16 153...
Page 597: ...Chapter 16 PLC Function CT2000 Series 16 156 This page intentionally left blank...