Chapter 16 PLC Function
CT2000 Series
16-77
API
EMUL
Multiplication of binary floating point numbers
122
D
P
Bit device
Word device
16-bit command
-
-
-
-
32-bit command (13 STEP)
DEMUL
Continuous
execution type
DEMULP
Pulse
execution type
Flag signal: none
X Y M K H KnX
KnY
KnM
T
C
D
S1
*
*
*
S2
*
*
*
D
*
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
S
1
: multiplicand.
S
2
: multiplier.
D
: product.
When the content of the register designated by
S
1
is multiplied by the content of
the register designated by
S
2
, the product will be stored in the register
designated by
D
; multiplication is performed entirely using binary floating-point
numbers.
If the source operand S
1
or
S
2
designates a constant K or H, the command will
transform that constant into a binary floating point number for use in
multiplication.
In the situation when S
1
and
S
2
designate identical register numbers, if a
"continuous execution" command is employed, when conditional contact is On,
the register will perform multiplication once during each scan. Pulse execution
type commands (DEMULP) are generally used under ordinary circumstances.
When X1=On, the binary floating point number (D1, D0) will be multiplied by the
binary floating point number (D11, D10), and the product will be stored in the
register designated by (D21, D20).
X1
DEMUL
D0
D10
D20
When X2 =On, the binary floating point number (D1, D0) will be multiplied from
K1234 (which has been automatically converted to a binary floating-point
number), and the results stored in (D11, D10).
X2
DEMUL
D0
K1234
D10
Summary of Contents for CT2000 Series
Page 5: ...Chapter 1 Introduction CT2000 Series 1 2 Model Name VFD 750 CT 43 F 00 A6 Serial Number...
Page 22: ...Chapter 1 Introduction CT2000 Series 1 19 Digital Keypad KPC CC01 KPC CE01 Unit mm inch...
Page 23: ...Chapter 1 Introduction CT2000 Series 1 20 This page intentionally left blank...
Page 41: ...Chapter 4 Wiring CT2000 Series 4 6 This page intentionally left blank...
Page 71: ...Chapter 7 Optional Accessories CT2000 Series 7 18 Wall Mounting Embedded Mounting...
Page 87: ...Chapter 8 Optional Cards CT2000 Series 8 8 PG Card intallation...
Page 88: ...Chapter 8 Optional Cards CT2000 Series 8 9 Disconneting the extension card...
Page 92: ...Chapter 8 Optional Cards CT2000 Series 8 13 PG2 Wiring Diagram...
Page 95: ...Chapter 8 Optional Cards CT2000 Series 8 16 PG2 Wiring Diagram...
Page 117: ...Chapter 8 Optional Cards CT2000 Series 8 38 This page intentionally left blank...
Page 259: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 11...
Page 260: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 12...
Page 263: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 15...
Page 266: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 18...
Page 397: ...Chapter 13 Warning Codes CT2000 Series 13 8 This page intentionally left blank...
Page 407: ...Chapter 14 Fault Codes and Descriptions CT2000 Series 14 10 This page intentionally left blank...
Page 489: ...Chapter 16 PLC Function CT2000 Series 16 48 LD X1 Load Contact a of X1 OUT Y1 Drive Y1 coil...
Page 592: ...Chapter 16 PLC Function CT2000 Series 16 151...
Page 594: ...Chapter 16 PLC Function CT2000 Series 16 153...
Page 597: ...Chapter 16 PLC Function CT2000 Series 16 156 This page intentionally left blank...