10-4 Digital Keypad KPC-CC01 Fault Codes and Descriptions
Following fault codes and description are for digital keypad KPC-CC01 with version V1.01 and version
higher.
LCM Display *
Description
Corrective Actions
FrEr
kpdFlash Read Er
Fault
Keypad flash memory read error
An error has occurred on keypad’s flash memory.
1.
Press RESET on the keypad to clear errors.
2.
Verify what kind of error has occurred on
keypad’s flash memory.
3.
Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
authorized local dealer.
FSEr
kpdFlash Save Er
Fault
Keypad flash memory save error
An error has occurred on keypad’s flash memory.
1. Press RESET on the keypad to clear errors.
2. Press RESET on the keypad to clear errors.
3. Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
authorized local dealer.
FPEr
kpdFlash Pr Er
Fault
Keypad flash memory parameter
error
Errors occurred on parameters of factory setting.
It might be caused by firmware update.
1. Press RESET on the keypad to clear errors.
2. Verify if there’s any problem on Flash IC.
3. Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
local authorized dealer.
VFDr
Read VFD Info Er
Fault
Keypad flash memory when
read AC drive data error
Keypad can’t read any data sent from VFD.
1. Verify if the keypad is properly connect to the
motor drive by a communication cable such as
RJ-45.
2. Press RESET on the keypad to clear errors.
3. Shut down the system, wait for ten minutes,
and then power on again the system.
If none of the solution above works, contact your
local authorized dealer.
CPUEr
CPU Error
Fault
and then power on again the
system.
A Serious error has occurred on keypad’s CPU.
1. Verify if there’s any problem on CPU clock?
2. Verify if there’s any problem on Flash IC?
3. Verify if there’s any problem on RTC IC?
4. Verify if the communication quality of the
RS485 is good?
5. Shut down the system, wait for ten minutes,
and then power on again the system. If none of
the solution above works, contact your local
authorized dealer.
Summary of Contents for CT2000 Series
Page 5: ...Chapter 1 Introduction CT2000 Series 1 2 Model Name VFD 750 CT 43 F 00 A6 Serial Number...
Page 22: ...Chapter 1 Introduction CT2000 Series 1 19 Digital Keypad KPC CC01 KPC CE01 Unit mm inch...
Page 23: ...Chapter 1 Introduction CT2000 Series 1 20 This page intentionally left blank...
Page 41: ...Chapter 4 Wiring CT2000 Series 4 6 This page intentionally left blank...
Page 71: ...Chapter 7 Optional Accessories CT2000 Series 7 18 Wall Mounting Embedded Mounting...
Page 87: ...Chapter 8 Optional Cards CT2000 Series 8 8 PG Card intallation...
Page 88: ...Chapter 8 Optional Cards CT2000 Series 8 9 Disconneting the extension card...
Page 92: ...Chapter 8 Optional Cards CT2000 Series 8 13 PG2 Wiring Diagram...
Page 95: ...Chapter 8 Optional Cards CT2000 Series 8 16 PG2 Wiring Diagram...
Page 117: ...Chapter 8 Optional Cards CT2000 Series 8 38 This page intentionally left blank...
Page 259: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 11...
Page 260: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 12...
Page 263: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 15...
Page 266: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 18...
Page 397: ...Chapter 13 Warning Codes CT2000 Series 13 8 This page intentionally left blank...
Page 407: ...Chapter 14 Fault Codes and Descriptions CT2000 Series 14 10 This page intentionally left blank...
Page 489: ...Chapter 16 PLC Function CT2000 Series 16 48 LD X1 Load Contact a of X1 OUT Y1 Drive Y1 coil...
Page 592: ...Chapter 16 PLC Function CT2000 Series 16 151...
Page 594: ...Chapter 16 PLC Function CT2000 Series 16 153...
Page 597: ...Chapter 16 PLC Function CT2000 Series 16 156 This page intentionally left blank...