Chapter 16 PLC Function
CT2000 Series
16-26
Input/output
Built-in three analog inputs and two analog outputs
Function expansion module Optional
Accessories
EMC-D42A; EMC-R6AA; EMCD611A
Communication Expansion
Module
Optional
Accessories
EMC-COP01,(CANopen)
16-5-1 Introduction to device functions
Input/output contact functions
Input contact X functions: Input contact X is connected with an input device, and reads input signals
entering the PLC. The number of times that contact a or b of input contact X is used in the program is
not subject to restrictions. The On/Off state of input contact X will change as the input device
switches On and Off; a peripheral device (WPLSoft) cannot be used to force contact X On or Off.
Output contact Y functions
The job of output contact Y is to send an On/Off signal to drive the load connected with output contact
Y. Output contacts consist of two types: relays and transistors. While number of times that contact a
or b of each output contact Y is used in the program is not subject to restrictions, it is recommended
that the number of output coil Y be used only once in a program, otherwise the right to determine the
output state when the PLC performs program scanning will be assigned to the program's final output
Y circuit.
Numerical value, constant [K]/[H]
Constant
Single-byte
K Decimal
K-32,768 ~ K32,767
Double-byte
K-2,147,483,648~K2,147,483,647
Single-byte
H Hexadecimal
H0000 ~ HFFFF
Double-byte
H00000000 ~ HFFFFFFFF
The PLC can use five types of numerical values to implement calculations based on its control tasks;
the following is an explanation of the missions and functions of different numerical values.
Binary Number, BIN
The PLC's numerical operations and memory employ binary numbers. Binary nibbles and relevant
terms are explained as follows:
Bit
Bits are the fundamental units of binary values, and have a state of either 1 or 0
Nibble
Comprised of a series of 4 bits (such as b3-b0); can be used to express a
one-nibble decimal number 0-9 or hexadecimal number: 0-F.
Byte
Comprised of a series of two nibbles (i.e. 8 bits, b7-b0); can express a
hexadecimal number: 00-FF.
Word
Comprised of a series of two bytes (i.e. 16 bits, b15-b0); can express a
hexadecimal number with four nibbles: 0000-FFFF.
Double Word
Comprised of a series of two words (i.e. 32 bits, b31-b0); can express a
hexadecimal number with eight nibbles: 00000000-FFFFFFFF
Summary of Contents for CT2000 Series
Page 5: ...Chapter 1 Introduction CT2000 Series 1 2 Model Name VFD 750 CT 43 F 00 A6 Serial Number...
Page 22: ...Chapter 1 Introduction CT2000 Series 1 19 Digital Keypad KPC CC01 KPC CE01 Unit mm inch...
Page 23: ...Chapter 1 Introduction CT2000 Series 1 20 This page intentionally left blank...
Page 41: ...Chapter 4 Wiring CT2000 Series 4 6 This page intentionally left blank...
Page 71: ...Chapter 7 Optional Accessories CT2000 Series 7 18 Wall Mounting Embedded Mounting...
Page 87: ...Chapter 8 Optional Cards CT2000 Series 8 8 PG Card intallation...
Page 88: ...Chapter 8 Optional Cards CT2000 Series 8 9 Disconneting the extension card...
Page 92: ...Chapter 8 Optional Cards CT2000 Series 8 13 PG2 Wiring Diagram...
Page 95: ...Chapter 8 Optional Cards CT2000 Series 8 16 PG2 Wiring Diagram...
Page 117: ...Chapter 8 Optional Cards CT2000 Series 8 38 This page intentionally left blank...
Page 259: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 11...
Page 260: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 12...
Page 263: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 15...
Page 266: ...Chapter 12 Description of Parameter Settings CT2000 Series 12 1 03 18...
Page 397: ...Chapter 13 Warning Codes CT2000 Series 13 8 This page intentionally left blank...
Page 407: ...Chapter 14 Fault Codes and Descriptions CT2000 Series 14 10 This page intentionally left blank...
Page 489: ...Chapter 16 PLC Function CT2000 Series 16 48 LD X1 Load Contact a of X1 OUT Y1 Drive Y1 coil...
Page 592: ...Chapter 16 PLC Function CT2000 Series 16 151...
Page 594: ...Chapter 16 PLC Function CT2000 Series 16 153...
Page 597: ...Chapter 16 PLC Function CT2000 Series 16 156 This page intentionally left blank...