76
Dell PowerConnect 55xx Systems User Guide
Startup Menu Procedures
The
Startup
menu enables performing various tasks, such as software
download, flash handling and password recovery.
You can enter the
Startup
menu when booting the device. User input must be
entered immediately after the POST test.
To enter the
Startup
menu:
• Turn the power on. After the auto-boot messages appear, the following
menu is displayed:
The following sections describe the available Startup menu options.
NOTE:
When selecting an option from the Startup menu, take time-out into
account. If no selection is made within 10 seconds (default), the device times out.
This default value can be changed through the CLI.
Download Software - Option
[1]
The software download procedure is used to replace corrupted files or
upgrade system software, when the device does not have IP connectivity or
when both software images of the device are corrupted and therefore you
cannot use the web-based management system.
NOTE:
it is highly recommended that, before loading via xmodem, the baud rate of
the device and terminal be set to 115200.
Startup Menu
[1]Download Software
[2]Erase Flash File
[3]Password Recovery Procedure
[4]Set Terminal Baud-Rate
[5]Stack menu
[6]Back