426
Dell PowerConnect 55xx Systems User Guide
GARP Timers
To enable a GARP timer on an interface:
1
Click
Switching
>
GARP
>
GARP Timers
in the tree view to open the
GARP Timers: Summary
page.
Figure 12-1. GARP Timers: Summary
The GARP timers are displayed.
2
Click
Edit
.
3
Select an interface, and enter the fields:
–
GARP Join Timer (10 - 2147483640)
— Enter the time, in
milliseconds, during which Protocol Data Units (PDU) are
transmitted.
–
GARP Leave Timer (10 - 2147483640
) — Enter the time interval, in
milliseconds, which the device waits before leaving its GARP state.
Leave time is activated by a Leave All Time message sent/received,
and cancelled by the Join message received. Leave time must be
greater than or equal to three times the join time.
–
GARP Leave All Timer (10 - 2147483640)
— Enter time interval, in
milliseconds, which all devices wait before leaving the GARP state.
The leave all time must be greater than the leave time
.
Summary of Contents for POWERCONNECT 5524