378
Dell PowerConnect 55xx Systems User Guide
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGSystemConfig.fm
D E LL C O N F ID E N T IA L – P R E L I M I N A RY 1 0 / 3 0/ 1 3 - F O R P R O O F O N LY
–
IPv6 Address Type
— When the server supports IPv6, this specifies
the type of static address supported. The possible options are:
•
Link Local
— A Link Local address that is non-routable and used
for communication on the same network only.
•
Global
— A globally unique IPv6 address; visible and reachable
from different subnets.
–
Link Local Interface
— When the server supports an IPv6 Link Local
address, this specifies the Link Local interface. The possible options
are:
•
None
— Disable the ISATAP tunnel.
•
ISATAP
— The IPv6 interface is configured on an ISATAP
tunnel.
–
IP Address
— Enter the receiver’s IP address.
4
Enter the fields:
–
Syslog Port Number
— Port to which SYSLOG message are sent.
–
Maximum Header Size (Bytes)
— Maximum number of bytes that
can be sent to the receiver in a single sample datagram (frame).
Adding an sFlow Receiver Using the CLI Commands
The following table summarizes the CLI commands for adding an sFlow
receiver.
Table 9-73. sflow Receiver CLI Commands
CLI Command
Description
sflow receiver
index
{
ipv4-
address
|
ipv6-address
|
hostname
}
[
port
port] [
max-datagram-siz
e
bytes]
no sflow receiver
index
Defines an sFlow receiver.
Use the no form of this command to
remove the definition of the receiver.
show sflow configuration
[
port_id
]
Displays the sFlow configuration for
ports that are enabled for Flow
sampling or Counters sampling.