Dell PowerConnect 55xx Systems User Guide
167
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGSystemConfig.fm
D E L L CO N F I D E N T I A L – P R E L I MI N A RY 10 / 3 0 /1 3 - FO R PR O O F O N LY
Managing PoE Using the CLI Commands
The following table describes the CLI commands for viewing fields displayed
on the
Power Over Ethernet
pages.
Table 9-4. Power Over Ethernet CLI Commands
CLI Command
Description
power inline {auto|never}
Configures the administrative
status of the inline power on an
interface.
power inline powered-device
pd-
type
no power inline powered-device
Adds a description of the powered
device type. Use the no version of
the command to remove the
description.
Use the no form of this command
to restore the default
configuration.
power inline priority
{
critical
|
high
|
low
}
no power inline priority
Configures the priority of the
interface from the point of view of
inline power management.
Use the no form of this command
to restore the default
configuration.
power inline
usage-threshold
no power inline
usage-threshold
Configures the threshold for
triggering alarms.
Use the no form of this command
to restore the default
configuration.
power inline traps enable
no power inline traps enable
Enables PoE device traps.
Use the no form of this command
to disable traps.
power inline limit-mode {max-
port-power|port}
no power inline limit-mode
Sets the power limit mode of the
system.
Use the no form of this command
to return to default.