Dell PowerConnect 55xx Systems User Guide
335
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Maintenance Projects\Dell
Contax\sources\CxUGSystemConfig.fm
D E L L CO N F I D E N T I A L – P R E L I MI N A RY 10 / 3 0 /1 3 - FO R PR O O F O N LY
–
Link Local Interface
— When the server supports an IPv6 Link Local
address, this specifies the Link Local interface. The possible options
are:
•
VLAN
— The IPv6 interface is configured on this VLAN.
•
ISATAP
— The IPv6 interface is configured on an ISATAP
tunnel.
–
Recipient IP
— The IP address to whom the traps are sent.
–
Notification Type
— The notification sent. The possible options are:
•
Trap
— Traps are sent.
•
Inform
— Informs are sent.
If SNMP versions 1 and 2 are enabled for the selected recipient, enter the
fields:
–
Community String
— The community string of the trap manager.
–
Notification Version
— The message trap SNMP version (v1 or v2).
If SNMPv3 is used to send and receive traps, enter the fields:
–
User Name
— The user to whom SNMP notifications are sent.
–
Security Level
— The means by which the packet is authenticated.
The possible options are:
•
No Authentication
— The packet is neither authenticated nor
encrypted.
•
Authentication
— The packet is authenticated.
•
Privacy
— The packet is both authenticated and encrypted.
3
Enter the fields for all versions of SNMP:
–
UDP Port (1-65535)
— The UDP port used to send notifications. The
default is 162.
–
Filter Name
— Select an SNMP filter from a list of previously-defined
SNMP filters.
–
Timeout (1-300)
— The amount of time (seconds) the device waits
before resending informs.
–
Retries (1-255)
— The amount of times the device resends an inform
request.