To disable I/O Identity Optimization, use the command:
racadm set idrac.ioidopt.IOIDOptEnable Disabled
To view the I/O Identity Optimization setting, use the command:
racadm get iDRAC.IOIDOpt
Configuring persistence policy settings
Using IO identity, you can configure policies specifying the system reset and power cycle behaviors that determine the persistence
or clearance of the virtual address, initiator, and storage target settings. Each individual persistence policy attribute applies to all
ports and partitions of all applicable devices in the system. The device behavior changes between auxiliary powered devices and
non-auxiliary powered devices.
NOTE: The Persistence Policy feature may not work when set to default, if the VirtualAddressManagement attribute is
set to FlexAddress mode on iDRAC and if the FlexAddress feature is disabled in CMC. Ensure that you set the
VirtualAddressManagement attribute to Console mode in iDRAC or enable the FlexAddress feature in CMC.
You can configure the following persistence policies:
•
Virtual Address: Auxiliary powered devices
•
Virtual Address: Non-Auxiliary powered devices
•
Initiator
•
Storage target
Before applying the persistence policy, make sure to:
•
Inventory the network hardware at least once, that is, enabled Collect System Inventory On Restart.
•
Enable I/O Identity Optimization.
Events are logged to the Lifecycle Controller log when:
•
I/O Identity Optimization is enabled or disabled.
•
Persistence policy is changed.
•
Virtual address, initiator and target values are set based on the policy. A single log entry is logged for the configured devices and
the values that are set for those devices when the policy is applied.
Event actions are enabled for SNMP, email, or WS-eventing notifications. Logs are also included in the remote syslogs.
Default values for persistence policy
Persistence Policy
AC Power Loss
Cold Boot
Warm Boot
Virtual Address: Auxiliary
Powered Devices
Not selected
Selected
Selected
Virtual Address: Non-Auxiliary
Powered Devices
Not selected
Not selected
Selected
Initiator
Selected
Selected
Selected
Storage Target
Selected
Selected
Selected
NOTE: When a persistent policy is disabled and when you perform the action to lose the virtual address, re-enabling the
persistent policy does not retrieve the virtual address. You must set the virtual address again after you enable the
persistent policy.
179