Using the Storage Management Service
141
omreport Fan Status
controller=id enclosure=
<ENCLOSUREID>
info=temps index=n
where
id
is the controller number
and the enclosure number and “n” is
the number of a temperature probe.
For example: controller=0
enclosure=2 info=temps index=1
Displays the specified
temperature probe.
Table 8-10.
omreport Fan Status
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs
Use
omreport storage enclosure
Displays property information for
all enclosures attached to the system.
controller=id enclosure=
<ENCLOSUREID> info=fans
where
id
is the controller number
and the enclosure number.
For example: controller=0
enclosure=2
NOTE:
For SCSI controllers, the ID
specified in enclosure=
<ENCLOSUREID> is the connector
number and for Serial Attached
SCSI (SAS) controllers, ID is the
connectorNumber:EnclosureIndex.
Displays the fans for the specified
enclosure.
controller=id enclosure=
<ENCLOSUREID>
info=fans index=n
where
id
is the controller number
and the enclosure number and “n”
is the number of a fan.
For example: controller=0
enclosure=2 info=fans index=1
Displays the specified fan.
Table 8-9.
omreport Temperature Probe Commands
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs
Use
Summary of Contents for Command Line Interface
Page 12: ...12 Contents ...
Page 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Page 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Page 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Page 134: ...134 omconfig rac Managing the Remote Access Controller ...
Page 186: ...186 Using the Storage Management Service ...
Page 214: ...214 Glossary ...
Page 226: ...26 Index 226 Index ...