148
Using the Storage Management Service
omconfig Enable Controller Alarm
Use the following
omconfig
command syntax to enable the controller alarm. See the online help for
more information about using this command.
Complete Syntax
omconfig storage controller action=enablealarm controller=id
where
id
is the controller ID as reported by the
omreport storage controller
command.
Example Syntax
For example, to enable the alarm on controller 1, enter:
omconfig storage controller action=enablealarm controller=1
omconfig Disable Controller Alarm
Use the following
omconfig
command syntax to disable the controller alarm. See the online help for
more information about using this command.
Complete Syntax
omconfig storage controller action=disablealarm controller=id
where
id
is the controller ID as reported by the
omreport storage controller
command.
Example Syntax
For example, to disable the alarm on controller 1, enter:
omconfig storage controller action=disablealarm controller=1
omconfig Quiet Controller Alarm
Use the following
omconfig
command syntax to silence an activated controller alarm. See the online
help for more information about using this command.
Complete Syntax
omconfig storage controller action=quietalarm controller=id
where
id
is the controller ID as reported by the
omreport storage controller
command.
Example Syntax
For example, to quiet the alarm on controller 1, enter:
omconfig storage controller action=quietalarm controller=1
Summary of Contents for Command Line Interface
Page 12: ...12 Contents ...
Page 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Page 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Page 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Page 134: ...134 omconfig rac Managing the Remote Access Controller ...
Page 186: ...186 Using the Storage Management Service ...
Page 214: ...214 Glossary ...
Page 226: ...26 Index 226 Index ...