omconfig rac: Managing the Remote Access Controller
129
omconfig rac remote
Use the
omconfig rac remote
command to specify the remote features property values. Table 7-9 shows
the valid parameters for the command.
Example Command
The following example sets one name=value pair.
Type:
omconfig rac remote floppytftpenable=true
The following message appears:
Command Successful. Please reset RAC card!
omconfig rac rmdialinuser
Use the
omconfig rac rmdialinuser
command to remove a dial-in user. Table 7-10 shows the valid
parameters for the command.
Table 7-9.
omconfig rac remote
name=value pair
Description
floppytftpenable=true | false
true
: Enables remote boot.
false
: Disables remote boot.
floppytftpipaddr=<
text
>
Sets the floppy TFTP address.
floppytftppath=<
text
>
Sets the floppy TFTP path.
fwupdatetftpipaddr=<
text
>
Sets the firmware TFTP address.
fwupdatetftppath=<
text
>
Sets the directory path on the TFTP server where the
firmware update images reside.
Table 7-10.
omconfig rac rmdialinuser
name=value pair
Description
username=<
text
>
Specifies the user name of entry which is to be deleted. If no
user name is specified, an index must be specified.
index=<
n>
Specifies the index of the entry which is to be deleted. If no
index is specified, a user name must be specified.
Summary of Contents for Command Line Interface
Page 12: ...12 Contents ...
Page 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Page 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Page 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Page 134: ...134 omconfig rac Managing the Remote Access Controller ...
Page 186: ...186 Using the Storage Management Service ...
Page 214: ...214 Glossary ...
Page 226: ...26 Index 226 Index ...