Using the Storage Management Service
137
User Privileges for omreport storage and omconfig storage
Storage Management requires Administrator privileges to use the
omconfig storage
command. User and
Power User privileges are sufficient to use the
omreport storage
command.
omreport Command
The following sections provide the
omreport
command syntax required to display the status of various
storage components.
pdisk=<PDISKID>
Indicates a particular physical disk by specifying either
connector:targetID
or
connector:enclosureID:portID.
To obtain the values for the connector, enclosure, and physical disk (targetID or
portID), you would enter
omreport storage controller
to display the controller IDs
and then enter
omreport storage pdisk controller=id
to display the IDs for the
physical disks attached to the controller.
battery=id
Indicates the battery ID as reported by the
omreport
command. To obtain this
value, enter
omreport storage controller
to display the controller IDs and then
enter
omreport storage battery controller=id
to display the ID for the
controller battery.
< >
The caret symbols (< >) enclose variable elements that you must specify.
For example, the
name=<string>
parameter might be specified as
name=
VirtualDisk1.
[ ]
The bracket symbols ([ ]) indicate optional elements that you can choose to
specify or not.
For example, when creating a virtual disk, the
[name=<string>]
parameter
indicates that you have the option of specifying the virtual disk name. If you omit
this parameter from the syntax, then a default name for the virtual disk is
chosen for you.
|
The pipe symbol (|) separates two or more options from which one only must
be selected.
For example, when creating a virtual disk, the
cachepolicy=d|c
indicates that the
cache policy must be specified as either
cachepolicy=d
or
cachepolicy=c
.
Table 8-2.
Syntax For Name=Value Pairs For Parameters
(continued)
Syntax
Description
Summary of Contents for Command Line Interface
Page 12: ...12 Contents ...
Page 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Page 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Page 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Page 134: ...134 omconfig rac Managing the Remote Access Controller ...
Page 186: ...186 Using the Storage Management Service ...
Page 214: ...214 Glossary ...
Page 226: ...26 Index 226 Index ...