136
Using the Storage Management Service
For example, the following
omconfig
command syntax for blinking a physical disk has three levels and
three name=value pairs:
omconfig storage pdisk action=blink controller=id pdisk=<PDISKID>
where PDISKID=<connector:enclosureID:portID | connector:targetID>
In this example, the
id
in
controller=id
is the controller number such that controller 1 would be
specified as controller=1.
Syntax for Required, Optional, and Variable Command Elements
The
omreport
and
omconfig
commands have multiple name=value pairs. These name=value pairs may
include required, optional, and variable parameters. The following table describes the syntax used to
indicate these parameters.
Table 8-2.
Syntax For Name=Value Pairs For Parameters
Syntax
Description
controller=id
Indicates the controller ID as reported by the
omreport storage controller
command. To obtain these values, enter
omreport storage controller
to display the
controller IDs and then enter
omreport storage pdisk controller=id
to display the
IDs for the physical disks attached to the controller.
For example, the
controller=id
parameter might be specified as
controller=1
.
connector=id
Indicates the connector ID as reported by the
omreport
command. To obtain this
value, enter
omreport storage controller
to display the controller IDs and then
enter
omreport storage connector controller=id
to display the IDs for the
connectors attached to the controller.
For example, the
connector=id
parameter might be specified as
connector=2
.
vdisk=id
Indicates the virtual disk ID as reported by the
omreport
command. To obtain this
value, enter
omreport storage controller
to display the controller IDs and then
enter
omreport storage vdisk controller=id
to display the IDs for the virtual disks
on the controller.
For example, the
vdisk=id
parameter might be specified as
vdisk=3
.
enclosure=
<ENCLOSUREID>
Indicates a particular enclosure by specifying either
enclosure=connector
or
enclosure=connector:enclosureID.
To obtain these values, you would enter
omreport storage controller
to display the
controller IDs and then enter
omreport storage enclosure controller=id
to display
the IDs for the enclosures attached to the controller.
Summary of Contents for Command Line Interface
Page 12: ...12 Contents ...
Page 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Page 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Page 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Page 134: ...134 omconfig rac Managing the Remote Access Controller ...
Page 186: ...186 Using the Storage Management Service ...
Page 214: ...214 Glossary ...
Page 226: ...26 Index 226 Index ...