76
omconfig: Managing Components Using the Instrumentation Service
The output from the
omconfig chassis remoteaccess
command lists each of the available configurations.
Table 4-3 shows the valid parameters:
Table 4-12.
omconfig chassis remoteaccess
name=value pair 1
config=
name=value pair 2
Description
config=advsol
characcuminterval=number
number
: Sets the character accumulate
interval in 5 millisecond intervals.
charsendthreshold=number
number
: Sets the number of characters. BMC
automatically sends a serial over LAN data
packet that contains this number of
characters as soon as this number of
characters (or greater) has been accepted
from the baseboard serial controller into
the BMC.
config=nic
enable=true | false
true
: Enables IPMI over LAN.
false
: Disables IPMI over LAN.
encryptkey=text
confirmencryptkey=text
text:
Text used for encryption and
confirmation of encryption.
NOTE:
The option
text
is supported only on
PowerEdge
x
9
xx
systems.
gateway=Gateway
Gateway
: Sets a gateway address if you have
selected static as the IP address source for the
BMC LAN interface.
enablenic=true | false
true
: Enables DRAC NIC.
false
: Disables DRAC NIC
NOTE:
The option
enablenic
is supported on
PowerEdge
x
9
xx
systems that have DRAC 5
installed.
IP address=IP
ip
: Sets the IP address if you have selected
static as the IP address source for the BMC
LAN interface.
Summary of Contents for Command Line Interface
Page 12: ...12 Contents ...
Page 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Page 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Page 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Page 134: ...134 omconfig rac Managing the Remote Access Controller ...
Page 186: ...186 Using the Storage Management Service ...
Page 214: ...214 Glossary ...
Page 226: ...26 Index 226 Index ...