omconfig: Managing Components Using the Instrumentation Service
91
Example Set Alert Action Commands
The examples below are valid example commands. For each successful command issued, the following
message appears:
Alert action(s) configured successfully.
Example Current Probe Actions
To disable system console alert if a current probe detects a warning event, type:
omconfig system alertaction event=currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail broadcast=true
Example Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=true
Example Chassis Intrusion Actions
To clear all alert actions for chassis intrusion, type:
omconfig system alertaction event=intrusion clearall=true
event=powersupplywarn
Sets actions when a power supply probe detects a warning value.
event=processorwarn
Sets actions when a processor probe detects a warning value.
event=processorfail
Sets actions when a processor probe detects a failure value.
event=redundegrad
Sets actions when a redundant component becomes inoperative, resulting in
less than full redundancy for that component.
event=redunlost
Sets actions when one or more redundant components become inoperative,
resulting in a lost or a "no redundant components working" condition for
that component.
event=tempwarn
Sets actions when a temperature probe detects a warning value.
event=tempfail
Sets actions when a temperature probe detects a failure value.
event=voltwarn
Sets actions when a voltage probe detects a warning value.
event=voltfail
Sets actions when a voltage probe detects a failure value.
event=watchdogasr
Sets actions that Server Administrator performs on the next system startup
after a watchdog Automatic System Recovery (ASR) is performed for a hung
operating system.
Table 4-21.
Events for Which You Can Set Alert Actions
(continued)
Event Name
Description
Summary of Contents for Command Line Interface
Page 12: ...12 Contents ...
Page 50: ...50 omreport Viewing System Status Using the Instrumentation Service ...
Page 100: ...100 omconfig Managing Components Using the Instrumentation Service ...
Page 118: ...118 omreport rac Viewing Remote Access Controller Components ...
Page 134: ...134 omconfig rac Managing the Remote Access Controller ...
Page 186: ...186 Using the Storage Management Service ...
Page 214: ...214 Glossary ...
Page 226: ...26 Index 226 Index ...