Set Charge for Target Market
1238 CHG:REGION
Set Charge for Geographic Region
Use the SP to set the charge for the areas listed below.
0: Enable geographical area setting
1: Japan
2: NA (North America)
3: Europe
4: China (Mainland)
5: China (Taiwan) "5" and "4" refer to same pitch table.
6: Asia. "4" "5" "6" refer to same charge pitch table
If any item other than "0" is selected that item and its setting is enabled and takes priority.
[0 to 255/0/1/---]
Print Head Temperature Thresholds
1300 HTEMP:H:STOP
Trigger Shutdown: Standby, Printing
1301 HTEMP:H:JUDG
Trigger Shutdown: Power On
1302 HTEMP:H:RCVR
Recovery After High Temp Shutdown
1303 HTEMP:L:RCVR
Recovery After Low Temp Shutdown
1304 HTEMP:L:JUDG
Trigger Shutdown: Power On
1305 HTEMP:L:STOP
Trigger Shutdown: Standby, Printing
Use this SP to set the threshold for the operating temperature range of the print head.
[0 to 65535/0/1/0.1
o
C
Ambient Temperature Thresholds
1306 ETEMP:H:STOP
High Temperature to Trigger Shutdown: Standby, Printing
1307 ETEMP:H:JUDG
High Temperature to Trigger Shutdown: Power On
1308 ETEMP:H:RCVR
Recovery After High Temp Shutdown
5. Service Tables
242
5
Summary of Contents for J012
Page 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change ...
Page 25: ...24 ...
Page 63: ...1 Installation 62 1 ...
Page 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4 ...
Page 159: ...4 Troubleshooting 158 4 ...
Page 160: ...Self Diagnostic Test Flow 159 4 ...
Page 199: ...4 Troubleshooting 198 4 ...
Page 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6 ...
Page 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6 ...
Page 341: ...6 Detailed Section Descriptions 340 6 ...
Page 364: ...MEMO 363 ...
Page 365: ...MEMO 364 ...