Front Fan
Preparation
• Remove platen or ADF
• Raise the scanner unit to full upright.
• Remove: (1) paper cassette, (2) paper output tray, (3) right front cover, (4) right cover.
1. Pull the fan connector harness [1] out of its L-clamp.
1. Disconnect the fan harness connector [2] (
x1).
2. Remove fan bracket screws [3] and [4] then remove the fan (
x2).