1006
REG:TR2:GLOS:F
Adjust Main Scan Registration (Tray 2: Glossy Paper: FA)
Use this SP code to adjust writing in the main scan direction for glossy paper loaded in Tray
2. Do this setting when registration does not match the image start position on the user image
adjustment menu.
[-128 to +127/FA/1/0.1 mm]
1007
REG:MAN:GLOS:F
Adjust Main Scan Registration (Bypass: Glossy Paper: FA)
Use this SP code to adjust writing in the main scan direction for glossy paper loaded in the
bypass tray. Do this setting when registration does not match the image start position on the
user image adjustment menu.
[-128 to +127/FA/1/0.1 mm]
1008
REG:FD:OHP:F
Adjust Sub Scan Registration (OHP: FA)
Use this SP code to adjust writing in the sub scan direction for transparencies (OHP). Do this
setting when registration does not match the direction of paper feed selected in the user image
adjustment menu.
[-128 to +127/FA/1/0.1 mm]
1009
REG:TR1:OHP:F
Adjust Main Scan Registration (Tray 1: OHP: FA)
Use this SP code to adjust writing in the main scan direction for transparencies (OHP) loaded
in Tray 1. Do this setting when registration does not match the image start position on the user
image adjustment menu.
[-128 to +127/FA/1/0.1 mm]
1010
REG:MAN:OHP:F
Adjust Main Scan Registration (Bypass: OHP: FA)
Use this SP code to adjust writing in the main scan direction for transparencies (OHP) loaded
in the bypass tray. Do this setting when registration does not match the image start position
on the user image adjustment menu.
[-128 to +127/FA/1/0.1 mm]
1011
REG:FD2:NORM:F
Adjust Sub Scan Registration (Normal Paper: 2nd Registration:
FA)
Use this SP code to adjust writing in the sub scan registration for normal paper. Do this setting
when it is necessary to fine adjust the line feed position.
[-128 to +127/FA/1/0.1 mm]
1012
REG:FD2:GLOS:F
Adjust Sub Scan Registration (Glossy Paper: 2nd Registration:
FA)
5. Service Tables
232
5
Summary of Contents for J012
Page 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change ...
Page 25: ...24 ...
Page 63: ...1 Installation 62 1 ...
Page 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4 ...
Page 159: ...4 Troubleshooting 158 4 ...
Page 160: ...Self Diagnostic Test Flow 159 4 ...
Page 199: ...4 Troubleshooting 198 4 ...
Page 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6 ...
Page 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6 ...
Page 341: ...6 Detailed Section Descriptions 340 6 ...
Page 364: ...MEMO 363 ...
Page 365: ...MEMO 364 ...