2200 TH:PRG:HUMI1
35% Humidity
2201 TH:PRG:HUMI2
65% Humidity
Use this SP to set the threshold value in the humidity table switches to the table for air venting
during printing.
• SP2200: Looks up the low humidity table (35%).
• SP2201: Looks up the high humidity table (65%).
[0 to 100/0/1/
o
C.]
2202 TH:PRG:TM
For Future Use. Use this SP to set the threshold time for the printer to flush the print heads before
the start of a print job.
[0 to 4294967295/0/1/nl]
Group 3000
Adjust Printhead Gap for dpi
3000 GAP:300:H1:G:F
Print Head 1: 300 dpi: 1st Pass
3001 GAP:300:H1:B:F
Print Head 1: 300 dpi: 2nd Pass
3002 GAP:300:H2:B:F
Print Head 2: 300 dpi: 2nd Pass
3003 GAP:300:H3:G:F
Print Head 3: 300 dpi: 1st Pass
3004 GAP:300:H3:B:F
Print Head 3: 300 dpi: 2nd Pass
3005 GAP:300:H4:G:F
Print Head 4: 300 dpi: 1st Pass
3006 GAP:300:H4:B:F
Print Head 4: 300 dpi: 2nd Pass
[-128 to +127/FA/1/count.]
3007 GAP:600:H1:G:F
Print Head 1: 600 dpi: 1st Pass
3008 GAP:600:H1:B:F
Print Head 1: 600 dpi: 2nd Pass
3009 GAP:600:H2:B:F
Print Head 2: 600 dpi: 2nd Pass
3010 GAP:600:H3:G:F
Print Head 3: 600 dpi: 1st Pass
5. Service Tables
246
5
Summary of Contents for J012
Page 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change ...
Page 25: ...24 ...
Page 63: ...1 Installation 62 1 ...
Page 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4 ...
Page 159: ...4 Troubleshooting 158 4 ...
Page 160: ...Self Diagnostic Test Flow 159 4 ...
Page 199: ...4 Troubleshooting 198 4 ...
Page 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6 ...
Page 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6 ...
Page 341: ...6 Detailed Section Descriptions 340 6 ...
Page 364: ...MEMO 363 ...
Page 365: ...MEMO 364 ...