• Always work carefully around the machine with the scanner unit in the full upright position to avoid
hitting it and knocking it down onto the exposure glass.
Reinstallation
• Position both hinges on the left and right before you reattach the screws.
• Fasten one screw on the left hinge and one screw on the right hinge to make sure both hinges are
aligned, then reattach the other screws.
Paper Cassette, Output Tray
Here are some important points about cover removals:
• The scanner unit must be raised to the full upright position to remove the left and right covers.
• The scanner unit must be removed in order to remove the rear cover.
• The right inner cover does not need to be removed in order to remove the scanner unit.
• The tabs of the covers are fragile. Work carefully to avoid breaking the tabs during cover removal
and reinstallation.
1. Raise the output tray [1].
2. Pull the paper cassette [2] out partially, raise it slightly, then pull it out of the machine.
3. Lower the paper output tray.
4. Use the middle fingers of both hands to press the output tray arms [3] and [4] inward to release them,
then pull the output tray out of the machine.
Common Procedures
79
3
Summary of Contents for J012
Page 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change ...
Page 25: ...24 ...
Page 63: ...1 Installation 62 1 ...
Page 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4 ...
Page 159: ...4 Troubleshooting 158 4 ...
Page 160: ...Self Diagnostic Test Flow 159 4 ...
Page 199: ...4 Troubleshooting 198 4 ...
Page 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6 ...
Page 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6 ...
Page 341: ...6 Detailed Section Descriptions 340 6 ...
Page 364: ...MEMO 363 ...
Page 365: ...MEMO 364 ...