Maintenance?
NO
Service Mode
1. SERVICE'S CHOICE
YES
2. ADJUST
YES
3. VERSION DISPLAY
NO
5. CLEAR DATA
NO
6. FUNCTION
NO
8. H/W TEST
NO
9. COUNTER SETTING
NO
6. FUNCTION
Use these items to test the machine operation.
ADF FEED TEST
Tests original feed
Use this function to test the operation of original feed through the ARDF. Originals fed through the ARDF
for this test are not counted.
To do the test:
1. Set the originals in the ARDF.
2. Press [Start] to start the test.
3. Choose either "1-sided" or "2-sided" for either simplex or duplex testing.
4. Press [Clear/Stop] to stop the test at any time.
CCD MOVE TO HOME
Moves the CCD to its home position
Use this function to move the slider to the home position on the left. This prepares the machine for shipping
from the factory or moving the machine to another location. This operation does not affect the scan counter.
FAX RES. COPY
Tests the fax resolution
Use this function to test fax resolution. This allows testing without actually sending a fax to a remote machine;
the data is redirected to the machine's own coding unit and printed out.
Note:
• This function is available for the fax models only.
Service Mode
213
5
Summary of Contents for J012
Page 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change ...
Page 25: ...24 ...
Page 63: ...1 Installation 62 1 ...
Page 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4 ...
Page 159: ...4 Troubleshooting 158 4 ...
Page 160: ...Self Diagnostic Test Flow 159 4 ...
Page 199: ...4 Troubleshooting 198 4 ...
Page 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6 ...
Page 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6 ...
Page 341: ...6 Detailed Section Descriptions 340 6 ...
Page 364: ...MEMO 363 ...
Page 365: ...MEMO 364 ...