Code
Possible Cause
0023
Received PWD error in RSD or upgrade firmware.
0029
Mailbox password not set or password mismatch for mailbox receiving.
0030
No signal received within 6 sec. at phase D.
0031
Received incorrect signal at phase D (not EOP, MPS,EOM,DCS PPS_Q, PPS_Q, etc).
0032
No carrier received within 6 sec. after sending MCF, RTP, or RTN signal.
0033
Received DCN signal at phase D between pages (not last page) .
0039
Data received in non-ECM mode but did not receive next line within 13.1 seconds.
003F
Remote machine TSI not defined for one touch or speed dial directory.
0040
No carrier signal received within 6 sec. after sending CTR.
0041
No carrier signal within 6 sec. after sending PPR.
0042
No correct signal received after sending RNR signal.
0043
Received incorrect signal at phase D in ECM mode.
0044
No carrier /FSK signal received within 6 sec. after sending MCF in ECM mode.
0047
No correct signal received after sending ERR signal.
0048
No correct signal received after receive PPS_PRI_Q. PRI_Q, orEOR_PRI_Q .
004A
Line power over threshold for 60 sec. after MCF. No FSK or carrier signal detected in ECM
mode.
004B
Correct FSK signal not detected even though FSK tone detected within 6 sec.
004C
Handshake failed during re-training or between page during V34 RX.
004E
Received DCN signal after DIS sent in V.34.
0050
No correct signal received after CJ signal sent in V.8 phase.
0051
No phase 3 signal sent after phase 2 within 20 sec. in V.34.
0053
Modem disconnected after phase 4 in V.34.
0054
Remote machine disconnected after phase 4 in V.8
0055
Received incorrect signal after DIS signal sent in V.34
SC Error Codes
173
4
Summary of Contents for J012
Page 1: ...Toscana C1a C1b C1bN Machine Code J012 J013 J014 SERVICE MANUAL July 2007 Subject to change ...
Page 25: ...24 ...
Page 63: ...1 Installation 62 1 ...
Page 158: ...Self Diagnostic Test Flow Self Diagnostic Test Flow 157 4 ...
Page 159: ...4 Troubleshooting 158 4 ...
Page 160: ...Self Diagnostic Test Flow 159 4 ...
Page 199: ...4 Troubleshooting 198 4 ...
Page 330: ...Basic Operation Initialization Sequence at Power On Basic Operation 329 6 ...
Page 340: ...3 Original Feed Motor 4 Pick up Roller ADF 339 6 ...
Page 341: ...6 Detailed Section Descriptions 340 6 ...
Page 364: ...MEMO 363 ...
Page 365: ...MEMO 364 ...