Super 80 Professional – AOM
NORMAL PROCEDURES
Section 3 Page 39
Super 80 Professional – Aircraft Operating Manual
Coolsky, 2018
APU ........................................................................................................................... AS REQUIRED
15.
The APU must be started prior to initiating one engine taxi. If one engine taxi will not be
initiated, start the APU approximately 2 minutes prior to gate arrival. Please refer to the
STARTING APU procedure guide on how to start the APU.
16.
Before shutting down the right engine, set the APU Air switch to ON…
17.
…and set the right Pneumatic X-Feed Valve Lever to OPEN (up).
R ENG (One engine taxi) .......................................................................................... SHUTDOWN
18.
For one engine taxi, the right engine is normally shutdown leaving the left engine running
for taxi operations.
19.
Set the right Fuel Lever to OFF. (located under the throttle handle, down position)
20.
Verify right engine shutdown by observing the right engine instruments dropping.