Super 80 Professional – AOM
NORMAL PROCEDURES
Section 3 Page 11
Super 80 Professional – Aircraft Operating Manual
Coolsky, 2018
FIRE WARNINGS ....................................................................................................................... TEST
118.
Press and hold the LOOPS TEST button to test the Engine Fire Warning system.
Check that the fire bell sounds, followed by vocal warning “Fire left engine” and “Fire
right engine”.
119.
Check that the red light in both ENG FIRE handles come on, both AGENT LOW
lights come on, and both MASTER CAUTION and MASTER WARNING lights come on.
120.
Also, check that all the FIRE DETECTOR LOOP lights on the ENGINE FIRE DETECT SYS
panel come on during the test. (All switches should be in the BOTH position)
REVERSE THRUST AND UNLOCK LIGHTS .................................................................................. OUT
121.
Check that Engine Reverse Thrust lights and Engine Reverse Unlock lights for both
engines are out.
ENGINE INSTRUMENTS ....................................................................................................... CHECK
122.
Check that all engine instruments read normal (zero).
THRUST RATING SYSTEM .......................................................................................................... TEST
123.
Push and hold the TEST button on the TRP. RAT should in12°C. EPR LIM
should indicate 2.04. Mode Selector lights and NO MODE light should be out.
124.
Release the test button. RAT should indicate ambient temperature. EPR LIM should
indicate 2.00 with failure flag in view. NO MODE light should come on. All Mode Selector
lights should be out.
125.
Press TO to turn the NO MODE light off.
FUEL QUANTITY ........................................................................................................................ TEST
126.
Push the Fuel Quantity Test button to test the Fuel Quantity Indication System.
Each individual tank quantity indicator should indicate 3000 LBS. The total fuel quantity
should read 9000 LBS, and Zero Fuel Weight should indicate current ZFW plus 9000 LBS.
FUEL PANEL, QUANTITY AND DISTRIBUTION ..................................................................... CHECK
127.
Check that total fuel on board is sufficient for the planned flight.
128.
Check the current fuel distribution against the Fuel Distribution Guide. (The Fuel
Distribution Guide can be found in the Aircraft Operating Manual, Section 15)
FUEL USED RESET ................................................................................................................... RESET
129.
Set the FUEL USED RESET switch to RESET (Momentary) to reset the fuel used
counters.
HYDRAULIC SYSTEMS......................................................................................................... CHECK
130.
Set the Aux Hydraulic Pump switch to OVRD and then to ON.
131.
Check that the right hydraulics pressure gauge indicates within the top green
band for both positions with R HYD PRESS LOW light out.
132.
Set the Transfer Pump switch to ON (Aux Hydraulic Pump still in OVRD or ON)
133.
Check that the left hydraulics pressure gauge indicates within green band with
the L HYD PRESS LOW light out.
134.
Check hydraulic quantities. Both readouts should read about 18 quarts.
135.
Set the Transfer Pump switch back to OFF.
136.
Set the Aux Hydraulic Pump switch back to OFF.